ICS 27.180 F 19 备案号:63143-2018 中华人民共和国电力行业标准 DL / T 1989 — 2019 电化学储能电站监控系统与电池管理系统 通信协议 Communication protocol between monitoring system and battery management system of electrochemical energy storage station 2019-06-04 发布 2019-10-01 实施 国家能源局 发 布 DL / T 1989 — 2019 目 次 前言 ····································II 1 范围 ······································································································································· 1 2 规范性引用文件 ··················································································································· 1 3 术语和定义 ··························································································································· 1 4 基本规定 ······························································································································· 2 5 通信协议结构 ······················································································································· 2 6 基于 DL/T 860.81 的通信协议 ····························································································· 3 7 基于 DL/T 634.5104 的通信协议 ························································································· 5 8 基于 GB/T 19582.3 的通信协议··························································································· 9 附录 A (资料性附录) 电化学储能电站电池管理系统设备信息 ··········14 附录 B (规范性附录) 电化学储能电站设备逻辑节点定义 ············16 I DL / T 1989 — 2019 前 言 本标准按照GB/T 1.1-2009给出的规则起草。 请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别这些专利的责 任。 本标准由中国电力企业联合会提出。 本标准由全国电力储能标准化技术委员会(SAC/TC 550)归口。 本标准的起草单位:南方电网科学研究院有限责任公司、南方电网调峰调频发电有限公 司、中国能源建设集团广东省电力设计研究院、中国电力科学研究院有限公司、国电南京自 动化股份有限公司、东莞钜威动力技术有限公司、北京四方继保自动化股份有限公司。 本标准主要起草人:陈波、谈赢杰、李勇琦、周钰、陆志刚、彭鹏、郭晓斌、陈盼盼、 何华伟、陈满、张会明、郑庆飞、魏雷远、张可可、王星光、贾红舟、王申强。 II DL / T 1989 — 2019 电化学储能电站监控系统与电池管理系统通信协议 1 范围 本标准规定了电化学储能电站监控系统与电池管理系统之间通信的基本原则、接口和基 于通信协议DL/T 860.81、DL/T 634.5104、GB/T 19582.3的报文规范。 本标准适用于以锂离子电池、铅酸电池、铅炭电池为储能载体,功率不小于500kW且额 定能量不小于500kWh的电化学储能电站,其他类型和规模的储能电站可参照本标准执行。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本 适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T 19582.1 基于Modbus协议的工业自动化网络规范 第1部分:Modbus应用协议 GB/T 19582.3 基于Modbus协议的工业自动化网络规范 第3部分:Modbus协议在TCP/IP 上的实现指南 GB/T 36276 电力储能用锂离子电池 GB/T 36280 电力储能用铅炭电池 DL/T 634.5101 远动设备及系统 第5-101部分:传输规约 基本远动任务配套标准 DL/T 634.5104 远动设备及系统 第5-104部分:传输规约 采用标准传输协议集的IEC 60870-5-101网络访问 DL/T 860.5 变电站通信网络和系统 第5部分:功能的通信要求和装置模型 DL/T 860.6 电力自动化通信网络和系统 第6部分:与智能电子设备有关的变电站内配 置描述语言 DL/T 860.71 变电站通信网络和系统 第7-1部分:变电站和馈线设备的基本通信结构 原理和模型 DL/T 860.72 变电站通信网络和系统 第7-2部分:变电站和馈线设备的基本通信结构 抽象服务通信接口(ACSI) DL/T 860.73 变电站通信网络和系统 第7-3部分:变电站和馈线设备的基本通信结构 公用数据类 DL/T 860.74 变电站通信网络和系统 第7-4部分:变电站和馈线设备的基本通信结构 兼容逻辑节点类和数据类 DL/T 860.81 变电站通信网络和系统 第8-1部分:特定通信服务映射(SCSM)对MMS(ISO 9506-1和ISO 9506-2)及ISO/IEC 8802-3的映射 3 术语和定义 GB/T 36276、GB/T 36280中的术语及下列术语和定义适用于本文件。 3.1 电池模块管理单元 battery management unit(BMU) 管理一个电池模块,监测电池状态(电压、温度等),并为电池提供通信接口的系统 。 3.2 电池簇管理单元 battery cluster management unit(BCMU) 1 DL / T 1989 — 2019 实现对电池簇日常管理和监控的系统。 3.3 电池系统管理单元 battery system management unit(BSMU) 实现对电池簇管理单元日常管理和监控的系统。 3.4 电池管理系统 battery management system(BMS) 监测电池的状态(温度、电压、电流、荷电状态等),为电池提供通信接口和保护的系 统,包括BMU、BCMU、BSMU三个层级。 3.5 储能变流器 power conversion system(PCS) 实现储能电池与实流电网之间实实能量实实的装置。 3.6 电化学储能电站 electrochemical energy storage station(EESS) 采用电化学电池作为储能元件,可进行电能存储、实实及释放的电站。 3.7 电池能量状态 state of energy(SOE) 反映电池反反能量状反,为电池反反能量为电池额定能量的为为。 3.8 电池健康状态 state of health(SOH) 在标准在件下电池在在满状态以一定在率放电在在在电压放出的能量与其对应的标在 额定能量的为为。 4 基本规定 4.1 监控系统与 BMS 通信协议应支持监控系统同时与多个 BMS 通讯,实现信息量采集和控 制数据传输,支持接入 BMS 数量不应少于 255 个,各通信链路应相互独立,监控系统与任一 BMS 通信异常不应影响系统中其它通信链路的数据实互。 4.2 监控系统与 BMS 采用以太网通信,通信协议结构应符合 TCP/IP 协议要求。 4.3 监控系统和 BMS 通信可采用 DL/T 860.81、DL/T 634.5104 或 GB/T 19582.3 通信协议。 4.4 BMS 信息模型及信息点表可依据 BMS 功能及应用需求进行扩展。 5 5.1 通信协议结构 通信协议结构应采用基于 TCP/IP 通信协议的五层模型,结构见表 1。 表1 通信协议结构 应用数据单元 应用协议控制信息 应用层 传输接口 TCP/IP协议子集 2 传输层 DL / T 1989 — 2019 网络层 链路层 物理层 5.2 物理层应实现监控系统与 BMS 物理连接,宜采用屏蔽实绞线或光纤连接方式。监控系 统与 BMS 通信接口应支持 TCP/IP 网络接口,宜采用通信速率为 100Mbps 或 1000Mbps 的以太 网口。 5.3 链路层应采用平衡传输方式。 5.4 网络层应采用 IP 协议。站内以太网子网掩码应统一为 255.255.0.0 或 255.255.255.0; BMS 的 IP 地址应统一分配且站内唯一。 5.5 传输层应采用客户端-服务器模式建立 TCP 连接,监控系统应作为客户端,BMS 应作为 服务器端。采用 DL/T 860.81 的通信协议时,BMS 端口号应为 102。采用 DL/T 634.5104 的 通信协议时,BMS 端口号应为 2404。采用 GB/T 19582.3 的通信协议时,BMS 端口号应为 502。 5.6 应用层应能支持系统信号采集、监视、控制及故障管理,应分别遵循 DL/T 860.71、 DL/T 860.73、DL/T 860.74、DL/T 634.5104、GB/T 19582.1 的要求。 6 基于 DL/T 860.81 的通信协议 6.1 BMS 的信息模型应符合 DL/T 860.5、DL/T 860.71、DL/T 860.73、DL/T 860.74 的规 定,并应根据 DL/T 860.72、DL/T 860.

pdf文档 DL_T 1989-2019 电化学储能电站监控系统与电池管理系统通信协议

双碳政策标准 > 碳达峰碳中和标准 > 全国性标准 > 文档预览
22 页 0 下载 132 浏览 0 评论 0 收藏 3.0分
温馨提示:当前文档最多只能预览 5 页,若文档总页数超出了 5 页,请下载原文档以浏览全部内容。
本文档由 2023-06-11 10:26:18上传分享
给文档打分
您好可以输入 255 个字符
中国约定的碳达峰是哪一年( 答案:2030 )
评论列表
  • 暂时还没有评论,期待您的金玉良言